You can confidently purchase a Single Phase Solar Panel Inverter from our factory, assured of receiving unparalleled after-sales service and punctual delivery.
The Single Phase Solar Panel Inverter is an electronic converter that transforms DC (Direct Current) into AC (Alternating Current). Operating at frequencies typically under 60Hz, this inverter is tailored for single-phase electrical systems. Its low-frequency functionality brings advantages such as remarkable stability, reliability, reduced noise, and effective energy transformation. Available in a broad spectrum of power capacities to suit individual needs, these inverters often include safeguards like overvoltage, undervoltage, and overload protection. These inverters find widespread use in renewable energy systems, residential electrical systems, backup power solutions for industrial and commercial premises, and other scenarios demanding low-frequency power conversion.
Features of Single Phase Solar Panel Inverter:
Low Frequency Operation: Operating at frequencies generally below 60Hz, the inverter offers remarkable stability and reliability.
Excellent Efficiency: Designed for optimal energy conversion, this inverter minimizes energy loss, thereby cutting down electricity expenses.
Broad Power Spectrum: Available in various power output capacities, this inverter caters to a wide range of energy needs across diverse applications.
Comprehensive Protection Features: Equipped with multiple safeguards, including overvoltage, undervoltage, and overload protections, the inverter promises enhanced durability and longevity.
Intuitive Interface: The inverter boasts a user-friendly interface for effortless operation, monitoring, and customization.
Compact, Lightweight Design: Its compact and lightweight design facilitates easy installation and integration into various systems or applications.
Straightforward Maintenance: Requiring minimal maintenance, any necessary upkeep is simple and convenient.
Quiet Operation: Designed for low noise output, this inverter is perfect for environments demanding reduced noise levels.
Sturdy Construction: Made with top-quality materials, the inverter ensures longevity and durability, even in challenging environments.
Application Scenarios of Single Phase Solar Panel Inverter:
Renewable Energy Integration: This inverter integrates seamlessly into renewable energy setups, like wind and solar systems, efficiently converting DC to AC power.
Residential Electricity Solutions: Ideal for home electricity systems, the inverter facilitates low-frequency power conversion for a range of household appliances.
Power Backup Solutions: It serves as a reliable backup power source for industrial and commercial premises during outages or crises.
Powering Industrial Equipment: The inverter is capable of powering motors, compressors, and various industrial machines.
Telecom Backup and Support: In telecommunication systems, the inverter ensures uninterrupted power supply to vital communication devices and equipment.
Water Pumping Solutions: It converts DC power from solar panels to AC, driving water pumps in water distribution systems.
Critical Emergency Power: Essential in emergency vehicles like ambulances and fire trucks, the inverter powers life-saving equipment.
Maritime Applications: In marine settings, the inverter transforms DC power from battery banks into AC power, vital for operating various watercraft and boats.
Model: |
70112/24 (01 |
10212/24 (102) |
15224/48 (152) |
20224/48 (202) |
30224/48 (302) |
35248/96 (352) |
40248/96 402 |
50248/96 (502) |
60248/96 (602) |
70248/96/192 (702) |
||||||
Rated Power | 700W | 1000W | 1500W | 2000W | 3000W | 3500W | 4000W | 5000W | 6000W | 7000W | ||||||
Peak Power(20ms) | 2100VA | 3000VA | 4500VA | 6000VA | 9000VA | 10500VA | 12000VA | 15000VA | 18000VA | 21000VA | ||||||
Start Motor | 0.5HP | 1HP | 1.5HP | 2HP | 3HP | 3HP | 3HP | 4HP | 4HP | 5HP | ||||||
Battery Voltage | 12/24VDC | 12/24VDC | 24/48VDC | 24/48VDC | 24/48VDC | 48/96VDC | 48/96VDC | 48/96VDC | 48/96VDC | 48/96/192VDC | ||||||
Max AC charging current | 0A~20A(Depending on the model, The maximum charging power is 1/4 of the rated power) | |||||||||||||||
Built-in solar controller charging current (optional) | 10A~60A(PWM or MPPT) | 24/48V(PWM:10A~60A/MPPT:10A-100A) |
48V(PWM:10A~120A/MPPT:10A~100A)/ 96V(50A/100A(PWM or MPPT)) |
|||||||||||||
Size(L*W*Hmm) | 340x165x283 | 410x200x350 | 491x260x490 | |||||||||||||
Packing Size(L*W*Hmm) | 405x230x340(1pc)/475x415x350(2pc) | 475x265x410 | 545x315x550 | |||||||||||||
N.W. (kg) | 9.5(1pc) | 10.5(1pc) | 11.5(1pc) | 17 | 20.5 | 21.5 | 29 | 30 | 31.5 | 36 | ||||||
G.W. (kg)(Carton packaging) | 11(1pc) | 12(1pc) | 13(1pc) | 19 | 22.5 | 23.5 | 32 | 33 | 34.5 | 39 | ||||||
Installation Method | Tower | |||||||||||||||
Model: |
80248/96/192 ( 802) |
10348/96/192 (103) |
12396/192 (123) |
153192 (153) |
203192 (203) |
253240 (253) |
303240 (303) |
403384 (403) |
||||||||
Rated Power | 8KW | 10KW | 12KW | 15KW | 20KW | 25KW | 30KW | 40KW | ||||||||
Peak Power(20ms) | 24KVA | 30KVA | 36KVA | 45KVA | 60KVA | 75KVA | 90KVA | 120KVA | ||||||||
Start Motor | 5HP | 7HP | 7HP | 10HP | 12HP | 15HP | 15HP | 20HP | ||||||||
Battery Voltage | 48/96/192VDC | 48/96V/192VDC | 96/192VDC | 192VDC | 192VDC | 240VDC | 240VDC | 384VDC | ||||||||
Max AC charging current |
0A~40A(Depending on the model, The maximum charging power is 1/4 of the rated power) |
0A~20A(Depending on the model, The maximum charging power is 1/4 of the rated power) | ||||||||||||||
Built-in solar controller charging current (optional) |
PWM:(48V:120A; 96V:50A/100A; 192V/384V:50A) MPPT:(48V:100A/200A; 96V:50A/100A; 192V/384V:50A) |
50A/100A | 50A/100A | |||||||||||||
Size(L*W*Hmm) | 540x350x695 | 593x370x820 | 721x400x1002 | |||||||||||||
Packing Size(L*W*Hmm) | 600*410*810 | 656*420*937 | 775x465x1120 | |||||||||||||
N.W. (kg) | 66 | 70 | 77 | 110 | 116 | 123 | 167 | 192 | ||||||||
G.W. (kg)(Wooden packing) | 77 | 81 | 88 | 124 | 130 | 137 | 190 | 215 | ||||||||
Installation Method | Tower | |||||||||||||||
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) | ||||||||||||||
AC Input Voltage Range |
73VAC~138VAC(110VAC)/83VAC~148VAC(120VAC)/145VAC~275VAC(220VAC)/155VAC~285VAC(230VAC)/165VAC~295VAC(240VAC)(700W~7000W) 92VAC~128VAC(110VAC)/102VAC~138VAC(120VAC)/185VAC~255VAC(220VAC)/195VAC~265VAC(230VAC)/205VAC~275VAC(240VAC)(8KW~40KW) |
|||||||||||||||
AC Input Frequency Range | 45Hz~55Hz(50Hz)/55Hz~65Hz(60Hz) | |||||||||||||||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | |||||||||||||||
Output | Efficiency(Battery Mode) | ≥85% | ||||||||||||||
Output Voltage(Battery Mode) | 110VAC±2%/120VAC±2%/220VAC±2%/230VAC±2%/240VAC±2% | |||||||||||||||
Output Frequency(Battery Mode) | 50Hz±0.5 or 60Hz±0.5 | |||||||||||||||
Output Wave(Battery Mode) | Pure Sine Wave | |||||||||||||||
Efficiency(AC Mode) | ≥99% | |||||||||||||||
Output Voltage(AC Mode) | 110VAC±10%/120VAC±10%/220VAC±10%/230VAC±10%/240VAC±10%(For models below or equal to 7KW); Follow Input (For models above 7KW) | |||||||||||||||
Output Frequency(AC Mode) | Follow input | |||||||||||||||
Output waveform distortion(Battery Mode) | ≤3%(Linear load) | |||||||||||||||
No load loss(Battery Mode) | ≤1% rated power | |||||||||||||||
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode)) | |||||||||||||||
No load loss(Energy saving Mode) | ≤10W | |||||||||||||||
Battery Type (selectable) |
VRLA Battery | Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage) | ||||||||||||||
Customize battery |
Charging and discharging parameters of different types of batteries can be customized according to user requirements (charging and discharging parameters of different types of batteries can be set through the operation panel) |
|||||||||||||||
Protection | Battery undervoltage alarm | Factory default: 11V(Single battery voltage) | ||||||||||||||
Battery undervoltage protection | Factory default:10.5V(Single battery voltage) | |||||||||||||||
Battery overvoltage alarm | Factory default: 15V(Single battery voltage) | |||||||||||||||
Battery overvoltage protection | Factory default: 17V(Single battery voltage) | |||||||||||||||
Battery overvoltage recovery voltage | Factory default: 14.5V(Single battery voltage) | |||||||||||||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||||||||||||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||||||||||||||
Temperature protection | >90℃(Shut down output) | |||||||||||||||
Alarm | A | Normal working condition, buzzer has no alarm sound | ||||||||||||||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | |||||||||||||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | |||||||||||||||
Inside Solar controller (Optional) |
Charging Mode | PWM or MPPT | ||||||||||||||
PV Input Voltage Range |
PWM:15V-44V(12V system); 30V-44V(24V system);60V-88V(48V systerm);120V-176V(96V system); 240V-352V(192V system);300V-400V(240V system);480V-704V(384V system) MPPT:15V-120V(12V system); 30V-120V(24V system);60V-120V(48V system):120V-240V(96V system);240V-360V(192V system);300V-400V(240V system);480V-640V(384V system) |
|||||||||||||||
Max PV Input Voltage(Voc) (At the lowest temperature) |
PWM: 50V(12V/24V system); 100V(48V system); 200V(96V system); 400V(192V system); 500V(240V system);750V(384V system) MPPT:150V(12V/24V/48V system);300V(96V system); 450V(192V system); 500V(240V system);800V(384V system) |
|||||||||||||||
PV Array Maximum Power |
12V system: 140W(10A)/280W(20A)/420W(30A/560W(40A)/700W/(50A)/840W(60A/1120W(80A/1400W(100A); 24V system: 280W(10A)/560W(20A)/840W(30A/1120W(40A)/1400W(50A/1680W(60A)/2240W(80A)/2800W(100A); 48V system: 560W(10A/1120W(20A/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A/6720WPWM 120A/5.6KW&112KWIMPPT 100A/200A) 96V system: 5.6KW(50A)/11.2KW(100A); 192V system:(PWM:11.2KW(50A)/224KW(100A)/(MPPT:11.2KW(50A)/11.2*2KW(100A); 240V system:(PWMt14KW(50A)/28KW(100A))/(MPPT:14KW(50A)/14*2KW(100A); 384V system:(PWM:224KW(50A)/448KW(100A))/(MPPT224KW(50A)/224*2KW(100A) |
|||||||||||||||
Standby loss | ≤3W | |||||||||||||||
Maximum conversion efficiency | >95% | |||||||||||||||
Working Mode | Battery First/AC First/Saving Energy Mode | |||||||||||||||
Transfer Time | ≤4ms | |||||||||||||||
Display | LCD | |||||||||||||||
Thermal method | Cooling fan in intelligent control | |||||||||||||||
Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) | |||||||||||||||
Environment | Operating temperature | -10℃~40℃ | ||||||||||||||
Storage temperature | -15℃~60℃ | |||||||||||||||
Noise | ≤55dB | |||||||||||||||
Elevation | 2000m(More than derating) | |||||||||||||||
Humidity | 0%~95%,No condensation | |||||||||||||||
Warranty | 1 year |
Note:
1.Specifications are subject to change without prior notice;
2. Special voltage and power requirements can be customized according to the actual situation of users.