Southwire’s 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend. ST1 (low smoke) Rated for sizes 1/0 and larger. PVC jacket is made with SIM technology and has a coefficient of friction COF of 0.2. Cable can be installed in conduit without the aid of lubrication. Rated for 1000 lbs./FT maximum sidewall pressure.
Single core and multi-core cables with copper or aluminium conductor, XLPE insulated and PVC sheathed. Cables are rated at 0.6 / 1 (1.2) kV and conform to IEC 60502.
1 Conductor
Plain circular, compacted or shaped stranded copper or aluminium conductor, conform to IEC 60228 class 2.
2 Insulation
XLPE ( cross-linked polyethylene ) rated at 90 °C.
3 Colours for core identification
Single core - natural ( black on request )
Two core - red, black
Three core - red, yellow and blue
Four core - red, yellow, blue and black
Five core - red, yellow, blue, black and green/yellow
4 Assembly
Two, three, four or five insulated conductors are laid up together, if necessary filled with non-hygroscopic material compatible with the insulation. The filling may be omitted provided the outer shape of the cables remains practically circular and no adhesion occurs between cores and sheath.
5 Sheath
PVC type ST2 to IEC 60502, colour black.
Hints
If you know your product’s machine type, but not its product type or product name, try looking it up using the “Quick Path” on the DAYA Support site .A desktop is an “All-in-One desktop” if the monitor is in the same case as the CPU. Examples may include, but are not limited to, the IdeaCentre A and B Series, the ThinkCentre A70z, and the DAYA Essential C Series. Be careful to know whether you have a desktop or an All-in-One since they have different HTS numbers.
Please note:
The ECCN and HTS information provided on this web page is for general information purposes only and does not constitute advice by DAYA as to all relevant export and or import control regulation.
Our products are subject to the import and export laws of the locations in which we do business including, but not limited to, the EU, UK, US and China. Our products may not be shipped to any sanctioned location or party designated on any applicable sanctions lists. Specifically, our products may not be shipped to Cuba, Iran, North Korea, Syria, Crimea Region of Ukraine, Luhansk People's Republic and Donetsk People's Republic.
Size (AWG or KCM): 636.0
Stranding (AL/STL): 26/7
Diameter Inches: Aluminum: 0.1564
Diameter Inches: Steel: 0.1216
Diameter Inches: Steel Core: 0.3648
Diameter Inches: Cable OD: 0.990
Weight lb/1000FT: Aluminum: 499.
Weight lb/1000FT: Steel: 276.2
Weight lb/1000FT: Total: 874.1
Content %: Aluminum: 68.53
Content %: Steel: 31.47
Rate Breaking Strength (lbs.): 25,200
OHMS/1000ft: DC at 20ºC: 0.0267
OHMS/1000ft: AC at 75ºC: 0.033
Ampacity: 789 Amps
--100m/Coil with Shrinking Film Wrap, 6 Coils per outer carton.
--100m/Spool, spool can be Paper, Plastic, or ABS, then 3-4 spools per carton,
--200m or 250m per Drum, two drums per carton,
--305m/Wooden Drum, one drum per outer carton or pallet loading,
--500m/Wooden Drum, one drum per outer carton or pallet loading,
--1000m or 3000m wooden drum, then pallet loading.
*We can also offer customized OEM packing according to clients' request.
Port: Tianjin, or other ports as per your requirements.
Sea freight: FOB/C&F/CIF quotation are all available.
*For some countries such as Africa countries, middle east countries, our sea freight quotation is much cheaper than clients get from local shipping agency.
Nominal cross sectional area |
ELECTRICALDATA |
DIMENSIONSANDWEIGHTS |
Cable Code |
|||||
Max.Conductor Resistance |
Continuous Current Ratings |
Approx. overall diameter |
Approx. overall weight |
|||||
DC at 20 °C |
AC at 90 °C |
Laid in ground |
Laid in ducts |
Laid in free air |
||||
mm² |
Ω / km |
Ω / km |
A |
A |
A |
mm |
kg / km |
Two Core Cables |
6 rm 3.0800 3.9274 67 49 62 15.4 430 C213XA1020GMB01IMR |
10 rm 1.8300 2.3336 89 65 83 16.6 530 C314XA1020GMB01IMR |
16 rm 1.1500 1.4667 114 84 110 18.6 705 C315XA1020GMB01IMR |
25 rm 0.7270 0.9275 148 111 148 21.7 1000 C316XA1020GMB01IMR |
35 rm 0.5240 0.6688 177 134 180 23.8 1260 C317XA1020GMB01IMR |
Three Core Cables |
6 rm 3.0800 3.9274 55 40 52 16.2 500 C213XA1030GMB04IMR |
10 rm 1.8300 2.3336 74 54 70 17.9 615 C314XA1030GMB04IMR |
16 rm 1.1500 1.4667 95 70 93 20.1 835 C315XA1030GMB04IMR |
25 rm 0.7270 0.9275 123 92 124 23.4 1170 C316XA1030GMB04IMR |
35 sm 0.5240 0.6688 140 106 140 22.8 1390 C417XA1030GMB04IMR |
50 sm 0.3870 0.4944 166 128 171 25.8 1790 C418XA1030GMB04IMR |
70 sm 0.2680 0.3431 203 159 215 29.7 2495 C419XA1030GMB04IMR |
95 sm 0.1930 0.2481 243 193 263 33.3 3310 C445XA1030GMB04IMF |
120 sm 0.1530 0.1976 278 224 310 37.8 4430 C446XA1030GMB04IMF |
Four Core Cables |
4 rm 4.6100 5.8783 45 32 41 16.0 480 C212XA1040GMB08IMR |
6 rm 3.0800 3.9274 55 40 52 17.3 590 C213XA1040GMB08IMR |
10 rm 1.8300 2.3336 74 54 70 19.2 755 C314XA1040GMB08IMR |
16 rm 1.1500 1.4667 95 70 93 21.7 1020 C315XA1040GMB08IMR |
25 rm 0.7270 0.9275 123 92 124 25.4 1465 C316XA1040GMB08IMR |
35 sm 0.5240 0.6688 140 106 140 25.8 1780 C417XA1040GMB08IMR |
50 sm 0.3870 0.4944 166 128 171 29.5 2320 C418XA1040GMB08IMR |
70 sm 0.2680 0.3431 203 159 215 34.0 3235 C419XA1040GMB08IMR |
95 sm 0.1930 0.2481 243 193 263 38.1 4630 C445XA1040GMB08IMF |
120 sm 0.1530 0.1976 278 224 310 42.6 5760 C446XA1040GMB08IMF |
150 sm 0.1240 0.1612 310 252 349 47.1 6990 C447XA1040GMB08IMF |
185 sm 0.0991 0.1302 349 287 402 52.1 8590 C448XA1040GMB08IMS |
240 sm 0.0754 0.1012 402 335 473 58.3 10995 C449XA1040GMB08IMS |
300 sm 0.0601 0.0829 452 380 541 63.9 13550 C450XA1040GMB08IMS |
400 sm 0.0470 0.0676 511 435 627 72.9 17260 C451XA1040GMB08IMS |
500 sm 0.0366 0.0561 570 491 713 81.8 22775 C452XA1040GMB08IMS |
Four Core Cables with Reduced Neutral |
25rm 16rm 0.7270 / 1.1500 0.9275 / 1.4667 123 92 124 24.5 1370 C334XA1040GMB08IMR |
35sm 16rm 0.5240 / 1.1500 0.6688 / 1.4667 140 106 140 25.8 1635 C435XA1040GMB08IMR |
50sm 25rm 0.3870 / 0.7270 0.4944 / 0.9275 166 128 171 29.3 2135 C436XA1040GMB08IMR |
70sm 35sm 0.2680 / 0.5240 0.3431 / 0.6688 203 159 215 32.6 2905 C437XA1040GMB08IMR |
95sm 50sm 0.1930 / 0.3870 0.2481 / 0.4944 243 193 263 37.4 4160 C438XA1040GMB08IMF |
120sm 70sm 0.1530 / 0.2680 0.1976 / 0.3431 278 224 310 40.5 5185 C439XA1040GMB08IMF |
150sm 70sm 0.1240 / 0.2680 0.1612 / 0.3431 310 252 349 44.7 6165 C440XA1040GMB08IMF |
185sm 95sm 0.0991 / 0.1930 0.1302 / 0.2481 349 287 402 49.6 7650 C441XA1040GMB08IMF |
240sm 120sm 0.0754 / 0.1530 0.1012 / 0.1976 402 335 473 55.5 9735 C442XA1040GMB08IMS |
300sm 150sm 0.0601 / 0.1240 0.0829 / 0.1612 452 380 541 60.6 11940 C443XA1040GMB08IMS |
400sm 185sm 0.0470 / 0.0991 0.0676 / 0.1302 511 435 627 68.5 15100 C444XA1040GMB08IMS |
500sm 240sm 0.0366 / 0.0754 0.0561 / 0.1012 570 491 713 76.1 19270 C466XA1040GMB08IMS |
We provide technical support and complete power distribution solutions tailored to your needs. If the design drawings you provide are deemed unfeasible, we will optimize the plan and adjust it with the dimensions of the cabinet, the location of the equipment, and so on. We will also optimize the configuration of the products to make them meet your requirements.
If any problem occurs, we will first provide support by phone or email. We will perform a remote debug if necessary. Furthermore, our products come with a troubleshooting manual for reference when trying to find the fault and solve issues by yourself. Most problems can be solved by the above-mentioned methods. We will check in every year or so to acquire detailed information about your equipment to get a better understanding of the inner workings.
1. We will quickly solve the problem after receiving the issue report or repair request.
2. We then explain the cause of failure in detail and any fees will be charged according to market pricing.
3. If we take any parts back for inspecting, we will apply fragile notice stickers on them or write their serial number down to maintain the safety of the parts.
4. If your complaint is deemed valid, we will refund repair fees to you on-site.
1.Q: Are you a manufacturer or trader?
A:We are all, Main business of the company low-voltage switchgear, power distribution cabinet, explosion-proof cabinet design, production and system programming.
2.Q: Whether to support OEM/ODM?Can you design the equipment according to our size?
A: Of course, we can customize any product according to customer requirements, and we can provide design solutions and solutions.
3.Q: Why should I buy from you instead of someone else?
A: First of all, we can provide all customers with very professional support consisting of IT consultants and service teams.Secondly, our main engineers have more than 20 years of experience in power distribution equipment development.
4.Q:What about the delivery time?
A:Generally, our delivery time is around 7-15 days about. While, it depends on the requirement of customers and the
quantity of products.
5.Q:What about the shipment?
A:We can arrange shipment by DHL, FedEx, UPS,etc.of course, customers can also use their own freight forwarders.
6.Q:How about the terms of payment?
A:Supported T/T、Paypal、Apple Pay、Google Pay、Western Union,etc. Of course we can discuss on this.