Okoguard is Okonite's registered trade name for its exclusive ethylene-propylene rubber (EPR) based, thermosetting compound, whose optimum balance of electrical and physical properties is unequalled in other solid dielectrics. Okoguard insulation, with the distinctive red color and a totally integrated EPR system, provides the optimum balance for long, problem free service.
The Okolon TS-CPE jacket on this cable is a vulcanized chloronated polyethylene based compound which is mechanically rugged, flame, radiation and oil resistant.
Okoguard-Okolon TS-CPE 2 .4 kV cables are heavy duty nonshielded cables designed for use at up to 2.4 kV phase-to-phase in wet or dry locations in accordance with NEC. Okoguard-Okolon TS-CPE nonshielded cables are recommended for power distribution and motor circuits in generating plants and substations; in industrial and commercial buildings. Single conductors may be installed in industrial or commercial occupancies in triplexed or random lay in any raceway or duct in wet or dry locations, or in open runs as permitted by the NEC. Sizes 1/0 AWG and larger, may be installed in cable trays where permitted by NEC Section 315.32(3).
Conductor: Annealed uncoated copper compact stranded per ASTM B-496.
Strand Screen: Extruded semiconducting EPR strand screen. Meets or exceeds electrical and physical requirements of ICEA S-96-659/NEMA WC71 and UL 1072. Insulation: Meets or exceeds electrical and physical requirements of ICEA S-96659/NEMA WC71 and UL 1072.
Jacket: Meets or exceeds electrical and physical requirements of ICEA S-96659/NEMA WC71 for chlorinated polyethylene jackets. UL listed as Type MV-90, sunlight resistant, 40°C and for use in cable tray in accordance
with UL 1072. CSA listed as RW90 as 5kV non-shielded (FT4 1/0 and larger) -40°C in accordance with CSA C22.2 No 38. 1/C non-shielded cables can surface discharge in service when in a random phase spacing or when in contact with grounded surfaces.
• Okoguard cables meet or exceed all recognized industry standards (UL, CSA, NEMA/ICEA, IEEE).
• 90°C continuous operating temperature.
• 130°C emergency rating.
• 250°C short circuit rating.
• Passes UL and IEEE 383 and 1202/FT4 (1/0 and larger) Vertical Tray Flame Test.
• Sizes 500 kcmil and larger pass ICEA T-29-520 (210,000 BTU/hr) Vertical Tray Flame Test.
• Sizes 1/0 and larger pass CSA FT4 Vertical Tray Flame Test.
• Sizes #1 and smaller pass CSA FT1.
• Excellent corona resistance.
• Radiation resistant.
• Exceptional resistance to "treeing".
• Stress cones not required. • Moisture resistant.
• Resistant to most oils, acids, and alkalies.
• Sunlight Resistant.
• Sizes #4, #6 and #8 AWG are identified as FAA-L-824, Type B
Size (AWG or KCM): 636.0
Stranding (AL/STL): 26/7
Diameter Inches: Aluminum: 0.1564
Diameter Inches: Steel: 0.1216
Diameter Inches: Steel Core: 0.3648
Diameter Inches: Cable OD: 0.990
Weight lb/1000FT: Aluminum: 499.
Weight lb/1000FT: Steel: 276.2
Weight lb/1000FT: Total: 874.1
Content %: Aluminum: 68.53
Content %: Steel: 31.47
Rate Breaking Strength (lbs.): 25,200
OHMS/1000ft: DC at 20ºC: 0.0267
OHMS/1000ft: AC at 75ºC: 0.033
Ampacity: 789 Amps
--100m/Coil with Shrinking Film Wrap, 6 Coils per outer carton.
--100m/Spool, spool can be Paper, Plastic, or ABS, then 3-4 spools per carton,
--200m or 250m per Drum, two drums per carton,
--305m/Wooden Drum, one drum per outer carton or pallet loading,
--500m/Wooden Drum, one drum per outer carton or pallet loading,
--1000m or 3000m wooden drum, then pallet loading.
*We can also offer customized OEM packing according to clients' request.
Port: Tianjin, or other ports as per your requirements.
Sea freight: FOB/C&F/CIF quotation are all available.
*For some countries such as Africa countries, middle east countries, our sea freight quotation is much cheaper than clients get from local shipping agency.
Nominal cross sectional area |
ELECTRICALDATA |
DIMENSIONSANDWEIGHTS |
Cable Code |
||||||
Max.Conductor Resistance |
Continuous Current Ratings |
Approx. overall diameter |
Approx. overall weight |
||||||
DC at 20 °C |
AC at 70 °C |
Laid in ground |
Laid in ducts |
Laid in free air |
|||||
mm² |
Ω / km |
Ω / km |
A |
A |
A |
mm |
kg / km |
||
|
|
|
Two Co |
re Cables |
|
|
|
|
|
10 |
rm |
3.0800 |
3.7007 |
57 |
42 |
50 |
17.8 |
480 |
A314PA1020GCB01IMR |
16 |
rm |
1.9100 |
2.2950 |
74 |
55 |
67 |
19.8 |
590 |
A315PA1020GCB01IMR |
25 |
rm |
1.2000 |
1.4421 |
96 |
72 |
89 |
22.4 |
765 |
A316PA1020GCB01IMR |
35 |
rm |
0.8680 |
1.0433 |
114 |
87 |
109 |
25.0 |
945 |
A317PA1020GCB01IMR |
|
|
|
|
Three C |
ore Cables |
|
|
|
|
10 |
rm |
3.0800 |
3.7007 |
47 |
34 |
42 |
19.2 |
505 |
A314PA1030GCB04IMR |
16 |
rm |
1.9100 |
2.2950 |
61 |
45 |
56 |
21.4 |
625 |
A315PA1030GCB04IMR |
25 |
rm |
1.2000 |
1.4421 |
79 |
59 |
75 |
24.1 |
795 |
A316PA1030GCB04IMR |
35 |
sm |
0.8680 |
1.0433 |
88 |
66 |
82 |
24.0 |
865 |
A417PA1030GCB04IMR |
50 |
sm |
0.6410 |
0.7707 |
105 |
80 |
101 |
27.6 |
1100 |
A418PA1030GCB04IMR |
70 |
sm |
0.4430 |
0.5331 |
128 |
100 |
126 |
31.1 |
1410 |
A419PA1030GCB04IMR |
95 |
sm |
0.3200 |
0.3856 |
155 |
122 |
157 |
36.7 |
2165 |
A445PA1030GCB04IMF |
120 |
sm |
0.2530 |
0.3055 |
175 |
139 |
180 |
38.6 |
2490 |
A446PA1030GCB04IMF |
|
|
|
|
Four C |
ore Cables |
|
|
|
|
10 |
rm |
3.0800 |
3.7007 |
47 |
34 |
42 |
20.7 |
605 |
A314PA1040GCB08IMR |
16 |
rm |
1.9100 |
2.2950 |
61 |
45 |
56 |
23.1 |
735 |
A315PA1040GCB08IMR |
25 |
rm |
1.2000 |
1.4421 |
79 |
59 |
75 |
26.2 |
960 |
A316PA1040GCB08IMR |
35 |
sm |
0.8680 |
1.0433 |
88 |
66 |
82 |
27.3 |
1080 |
A417PA1040GCB08IMR |
50 |
sm |
0.6410 |
0.7707 |
105 |
80 |
101 |
32.1 |
1435 |
A418PA1040GCB08IMR |
70 |
sm |
0.4430 |
0.5331 |
128 |
100 |
126 |
36.9 |
2115 |
A419PA1040GCB08IMR |
95 |
sm |
0.3200 |
0.3856 |
155 |
122 |
157 |
40.8 |
2685 |
A445PA1040GCB08IMF |
120 |
sm |
0.2530 |
0.3055 |
175 |
139 |
180 |
44.6 |
3190 |
A446PA1040GCB08IMF |
150 |
sm |
0.2060 |
0.2494 |
196 |
158 |
206 |
49.3 |
3820 |
A447PA1040GCB08IMF |
185 |
sm |
0.1640 |
0.1994 |
222 |
181 |
237 |
54.5 |
4615 |
A448PA1040GCB08IMS |
240 |
sm |
0.1250 |
0.1533 |
257 |
212 |
281 |
61.0 |
5770 |
A449PA1040GCB08IMS |
300 |
sm |
0.1000 |
0.1240 |
290 |
242 |
323 |
67.1 |
6905 |
A450PA1040GCB08IMS |
400 |
sm |
0.0778 |
0.0984 |
333 |
281 |
378 |
76.1 |
8695 |
A451PA1040GCB08IMS |
500 |
sm |
0.0605 |
0.0789 |
377 |
322 |
436 |
85.0 |
11430 |
A452PA1040GCB08IMS |
|
|
|
Four C |
ore Cables |
with Reduc |
ed Neutral |
|
|
|
50sm |
25 rm |
0.6410 / 1.2000 |
0.7707 / 1.4421 |
105 |
80 |
101 |
31.5 |
1330 |
A436PA1040GCB08IMR |
70sm |
35sm |
0.4430 / 0.8680 |
0.5331 / 1.0433 |
128 |
100 |
126 |
34.1 |
1640 |
A437PA1040GCB08IMR |
95sm |
50sm |
0.3200 / 0.6410 |
0.3856 / 0.7707 |
155 |
122 |
157 |
39.1 |
2455 |
A438PA1040GCB08IMR |
120sm |
70sm |
0.2530 / 0.4430 |
0.3055 / 0.5331 |
175 |
139 |
180 |
42.9 |
2960 |
A439PA1040GCB08IMF |
150sm |
70sm |
0.2060 / 0.4430 |
0.2494 / 0.5331 |
196 |
158 |
206 |
46.9 |
3445 |
A440PA1040GCB08IMF |
185sm |
95sm |
0.1640 / 0.3200 |
0.1994 / 0.3856 |
222 |
181 |
237 |
51.6 |
4140 |
A441PA1040GCB08IMF |
240sm |
120sm |
0.1250 / 0.2530 |
0.1533 / 0.3055 |
257 |
212 |
281 |
58.0 |
5150 |
A442PA1040GCB08IMS |
300sm |
150sm |
0.1000 / 0.2060 |
0.1240 / 0.2494 |
290 |
242 |
323 |
63.8 |
6185 |
A443PA1040GCB08IMS |
400sm |
185sm |
0.0778 / 0.1640 |
0.0984 / 0.1994 |
333 |
281 |
378 |
72.1 |
7790 |
A444PA1040GCB08IMS |
500sm |
240sm |
0.0605 / 0.1250 |
0.0789 / 0.1533 |
377 |
322 |
436 |
80.7 |
10220 |
A466PA1040GCB08IMS |
We provide technical support and complete power distribution solutions tailored to your needs. If the design drawings you provide are deemed unfeasible, we will optimize the plan and adjust it with the dimensions of the cabinet, the location of the equipment, and so on. We will also optimize the configuration of the products to make them meet your requirements.
If any problem occurs, we will first provide support by phone or email. We will perform a remote debug if necessary. Furthermore, our products come with a troubleshooting manual for reference when trying to find the fault and solve issues by yourself. Most problems can be solved by the above-mentioned methods. We will check in every year or so to acquire detailed information about your equipment to get a better understanding of the inner workings.
1. We will quickly solve the problem after receiving the issue report or repair request.
2. We then explain the cause of failure in detail and any fees will be charged according to market pricing.
3. If we take any parts back for inspecting, we will apply fragile notice stickers on them or write their serial number down to maintain the safety of the parts.
4. If your complaint is deemed valid, we will refund repair fees to you on-site.
1.Q: Are you a manufacturer or trader?
A:We are all, Main business of the company low-voltage switchgear, power distribution cabinet, explosion-proof cabinet design, production and system programming.
2.Q: Whether to support OEM/ODM?Can you design the equipment according to our size?
A: Of course, we can customize any product according to customer requirements, and we can provide design solutions and solutions.
3.Q: Why should I buy from you instead of someone else?
A: First of all, we can provide all customers with very professional support consisting of IT consultants and service teams.Secondly, our main engineers have more than 20 years of experience in power distribution equipment development.
4.Q:What about the delivery time?
A:Generally, our delivery time is around 7-15 days about. While, it depends on the requirement of customers and the
quantity of products.
5.Q:What about the shipment?
A:We can arrange shipment by DHL, FedEx, UPS,etc.of course, customers can also use their own freight forwarders.
6.Q:How about the terms of payment?
A:Supported T/T、Paypal、Apple Pay、Google Pay、Western Union,etc. Of course we can discuss on this.